American Weathermakers logo

"We won't be comfortable until you are!"

Heating and Cooling Services
Maintenance & Repair | Installation

Call Today

847-509-2024 | 773-202-9898

Toll Free: 855-955-HVAC

Call Today - 847-509-2024

Share this page

American Weathermakers is the best choice for HVAC services in North Center, Chicago

Residents of this vibrant neighborhood turn to American Weathermakers for all of its HVAC needs. American Weathermakers has been a local business in the North Center community for decades. Our customers have trusted us to service their air conditioning and heating needs since 1949. American Weathermakers is a part of the community and enjoys servicing our friends and neighbors so they have the highest quality heating and cooling care. We strive towards making North Center one of the most comfortable places to live in the city of Chicago.

Many North Center residents refer to us by name because we’ve been the leading HVAC provider for their homes for years. We are well known for air conditioning and heating repairs and our customers rely on our progressive service for several other HVAC-related repairs and products, including:

Home Comfort Checkups - Our top recommended service to our North Center home owners is our Home Comfort Checkup.

Air Quality Control - North Center residents can consistently expect to get the best advice and products for air filter replacements, upgrades and repairs and humidity control.

Sump Pump Maintenance - There is a higher potential for floods in homes that have basements. Since many North Center homes do have basements, flooding is a regular concern. American Weathermakers will install or optimize your existing sump pump system to defend your home from water damage. 

Water Heaters - A standard family will use 2,000 gallons of hot water each month on average - if your water heater isn’t working correctly, it can be a source of a lot of money wasted and aggravation.

Boiler Services - American Weathermakers offers the products and services you require for all boiler system needs to keep you and your family warm and comfortable during cold winter months.

Home Zoning Systems - American Weathermakers can divide your home’s ductwork system into specific zones so you can heat or cool rooms at designated times. This practice will save you money and will prevent energy loss.

Insulation Services - If your home is older than a decade, it might not be as insulated as you thought it was. Insufficient insulation can result in lost temperature-controlled air and higher energy costs.

If any part of your HVAC system needs attention, turn to us to send a professional HVAC technician to your North Center home that can address all of your concerns and give you the most knowledgeable advice about what will work well for you and your home. Call us at (847) 509-7777 or contact us here to get service to your home in North Center today!

To learn more about North Center, Illinois, click here.

What we've been working on:


Map Provided club customer with annual preventative maintenance on 2 boilers and took measures to ensure the life expectancy of the equipment



Provided club customer with annual preventative maintenance on 2 boilers and took measures to ensure the life expectancy of the equipment


Map Provided club customer with annual preventative maintenance on American Standard furnace and humidifier and took measures to ensure the life expectancy of the equipment.



Provided club customer with annual preventative maintenance on American Standard furnace and humidifier and took measures to ensure the life expectancy of the equipment.


Map Arrived on call for no heat found inducer coming on right away but was giving me a pressure fault code check pressure switches all giving 24v tried turning furnace on with inducer unplugged and furnace fired up. Found pc board failing replaced with new universal pc board/hot rod hsi and cycled unit. Everything is functioning normally at this time



Arrived on call for no heat found inducer coming on right away but was giving me a pressure fault code check pressure switches all giving 24v tried turning furnace on with inducer unplugged and furnace fired up. Found pc board failing replaced with new universal pc board/hot rod hsi and cycled unit. Everything is functioning normally at this time


Map Arrived on call to replace warrantied inducer motor. Removed old inducer and gasket cleaned port and installed new inducer and reconnected everything back the way it was. Cycled unit to insure proper start up of inducer motor and operation. Everything is functioning normally at this time.



Arrived on call to replace warrantied inducer motor. Removed old inducer and gasket cleaned port and installed new inducer and reconnected everything back the way it was. Cycled unit to insure proper start up of inducer motor and operation. Everything is functioning normally at this time.


Map Arrived on call for no radiant heat. Vent rollout switch needing to be manually reset. Did a visual inspection of the flue pipe and found no blockages. Recommend replacing rollout switch if problems happens again.



Arrived on call for no radiant heat. Vent rollout switch needing to be manually reset. Did a visual inspection of the flue pipe and found no blockages. Recommend replacing rollout switch if problems happens again.


Map Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the life expectancy of the equipment.



Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the life expectancy of the equipment.


Map Arrived on call for no heat found inducer motor locked up and not operating on unit start up. Quoted customer on replacement of part and replacement of unit.



Arrived on call for no heat found inducer motor locked up and not operating on unit start up. Quoted customer on replacement of part and replacement of unit.


Map Provided customer with annual preventative maintenance on furnace and took measures to ensure the life expectancy of the equipment



Provided customer with annual preventative maintenance on furnace and took measures to ensure the life expectancy of the equipment


Map Arrived on call for no hot water recommended replacing unit. Will have installers out this afternoon for new system install



Arrived on call for no hot water recommended replacing unit. Will have installers out this afternoon for new system install


Map Arrived on call to find magic pax unit fan constantly running found blower control switch was on. Turned off cycled unit at thermostat to make sure everything still functioned. All good unit is all set for a/c



Arrived on call to find magic pax unit fan constantly running found blower control switch was on. Turned off cycled unit at thermostat to make sure everything still functioned. All good unit is all set for a/c


Map Arrived on call to find blower motor had seized. Replaced with century 3/4hp motor and cycled unit everything is functioning normally at this time.



Arrived on call to find blower motor had seized. Replaced with century 3/4hp motor and cycled unit everything is functioning normally at this time.


Map Provided club customer with annual preventative maintenance on electric furnace and took measures to ensure that the equipment has a lasting life expectancy



Provided club customer with annual preventative maintenance on electric furnace and took measures to ensure that the equipment has a lasting life expectancy


Map Provided club customer with annual preventative maintenance on furnace as well as there him and hot water heater and took measures to ensure the equipment has a lasting life expectancy



Provided club customer with annual preventative maintenance on furnace as well as there him and hot water heater and took measures to ensure the equipment has a lasting life expectancy


Map Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the equipment has a lasting life expectancy



Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the equipment has a lasting life expectancy


Map Tune up furnace, American Weathermakers



American Standard tune up


Map Provided club customer with annual preventative maintenance on 2 boilers and took measures to ensure the life expectancy of the equipment

Chicago, IL 60657, USA - 4 months ago

Provided club customer with annual preventative maintenance on 2 boilers and took measures to ensure the life expectancy of the equipment


Map Provided club customer with annual preventative maintenance on American Standard furnace and humidifier and took measures to ensure the life expectancy of the equipment.

Chicago, IL 60613, USA - 4 months ago

Provided club customer with annual preventative maintenance on American Standard furnace and humidifier and took measures to ensure the life expectancy of the equipment.


Map Arrived on call for no heat found inducer coming on right away but was giving me a pressure fault code check pressure switches all giving 24v tried turning furnace on with inducer unplugged and furnace fired up. Found pc board failing replaced with new universal pc board/hot rod hsi and cycled unit. Everything is functioning normally at this time

Chicago, IL 60618, USA - 4 months ago

Arrived on call for no heat found inducer coming on right away but was giving me a pressure fault code check pressure switches all giving 24v tried turning furnace on with inducer unplugged and furnace fired up. Found pc board failing replaced with new universal pc board/hot rod hsi and cycled unit. Everything is functioning normally at this time


Map Arrived on call to replace warrantied inducer motor. Removed old inducer and gasket cleaned port and installed new inducer and reconnected everything back the way it was. Cycled unit to insure proper start up of inducer motor and operation. Everything is functioning normally at this time.

Chicago, IL 60618, USA - 4 months ago

Arrived on call to replace warrantied inducer motor. Removed old inducer and gasket cleaned port and installed new inducer and reconnected everything back the way it was. Cycled unit to insure proper start up of inducer motor and operation. Everything is functioning normally at this time.


Map Arrived on call for no radiant heat. Vent rollout switch needing to be manually reset. Did a visual inspection of the flue pipe and found no blockages. Recommend replacing rollout switch if problems happens again.

Chicago, IL 60618, USA - 4 months ago

Arrived on call for no radiant heat. Vent rollout switch needing to be manually reset. Did a visual inspection of the flue pipe and found no blockages. Recommend replacing rollout switch if problems happens again.


Map Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the life expectancy of the equipment.

Chicago, IL 60618, USA - 4 months ago

Provided club customer with annual preventative maintenance on 2 furnaces and 2 humidifiers and took measures to ensure the life expectancy of the equipment.


Map Arrived on call for no heat found inducer motor locked up and not operating on unit start up. Quoted customer on replacement of part and replacement of unit.

Chicago, IL 60618, USA - 5 months ago

Arrived on call for no heat found inducer motor locked up and not operating on unit start up. Quoted customer on replacement of part and replacement of unit.


Map Provided customer with annual preventative maintenance on furnace and took measures to ensure the life expectancy of the equipment

Chicago, IL 60613, USA - 5 months ago

Provided customer with annual preventative maintenance on furnace and took measures to ensure the life expectancy of the equipment


Map Arrived on call for no hot water recommended replacing unit. Will have installers out this afternoon for new system install

Chicago, IL 60657, USA - 5 months ago

Arrived on call for no hot water recommended replacing unit. Will have installers out this afternoon for new system install


Map Arrived on call to find magic pax unit fan constantly running found blower control switch was on. Turned off cycled unit at thermostat to make sure everything still functioned. All good unit is all set for a/c

Chicago, IL 60657, USA - 6 months ago

Arrived on call to find magic pax unit fan constantly running found blower control switch was on. Turned off cycled unit at thermostat to make sure everything still functioned. All good unit is all set for a/c

Click Here to Join Our Comfort Club Happy Family Watching TV and recieve year round benefits
Video Library

HVAC Buying Guides
Click Here to download guides

Angies List 2018 Super Service Award Best North Shore Service Award Spring 2019 North Shore Choice Award 2019 Winner
Commercial Needs?

Visit Northern Weathermakers to learn about our commercial services.

Northern Weathermakers logo
Learn More - Click Here
Click Here to Join Our Comfort Club Recieve benefits year round
Click here for our special offers
Angies List 2018 Super Service Award Best North Shore Service Award Spring 2019
Video Library
Time to Buy?
Buying Guides

Research your next purchase using our Free Buying Guides

Before you make your next purchase, check out American Weathermakers' Buying Guides.

We have the information you need to make informed decisions when investing in new equipment for your home.

Click Here
Click here for our special offers
Testimonials
Mitsubishi Ductless Split System
Click here for our special offers
Schedule an Estimate Schedule Service
Online Services Ask an Expert
Referral Program Specials & Promotions
Towns & Villages We Serve What We're Working On
Site Map Privacy Policy Terms of Use

American Weathermakers, Inc. © 2002-2020

question_answer

{}

End Chat